
Anti-GLMN Antibody Picoband®
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
Glomulin is a protein that in humans is encoded by the GLMN gene. This gene encodes a phosphorylated protein that is a member of a Skp1-Cullin-F-box-like complex. The protein is essential for normal development of the vasculature and mutations in this gene have been associated with glomuvenous malformations, also called glomangiomas. Multiple splice variants encoding different isoforms have been found for this gene.
Boster Bio Anti-GLMN Antibody Picoband® catalog # A07319-1. Tested in WB, Flow Cytometry, ELISA applications. This antibody reacts with Human, Mouse, Rat. The brand Picoband indicates this is a premium antibody that guarantees superior quality, high affinity, and strong signals with minimal background in Western blot applications. Only our best-performing antibodies are designated as Picoband, ensuring unmatched performance.
GLMN
11146
Q92990
• Rabbit
Human, Mouse, Rat
E.coli-derived human GLMN recombinant protein (Position: Q153-R574) . Human GLMN shares 85.4% amino acid (aa) sequence identity with mouse GLMN.
• Polyclonal
WB, Flow Cytometry, ELISA
Immunogen affinity purified.
Adding 0.2 ml of distilled water will yield a concentration of 500 μg/ml.
Lyophilized
Adding 0.2 ml of distilled water will yield a concentration of 500 μg/ml.
1. Arai, T., Kasper, J. S., Skaar, J. R., Ali, S. H., Takahashi, C., DeCaprio, J. A. Targeted disruption of p185/Cul7 gene results in abnormal vascular morphogenesis. Proc. Nat. Acad. Sci. 100: 9855-9860, 2003. 2. Brouillard, P., Boon, L. M., Mulliken, J. B., Enjolras, O., Ghassibe, M., Warman, M. L., Tan, O. T., Olsen, B. R., Vikkula, M. Mutations in a novel factor, glomulin, are responsible for glomuvenous malformations ('glomangiomas') . Am. J. Hum. Genet. 70: 866-874, 2002. 3. Brouillard, P., Olsen, B. R., Vikkula, M. High-resolution physical and transcript map of the locus for venous malformations with glomus cells (VMGLOM) on chromosome 1p21-p22. Genomics 67: 96-101, 2000.
At -20°C for one year from date of receipt. After reconstitution, at 4°C for one month. It can also be aliquotted and stored frozen at -20°C for six months. Avoid repeated freezing and thawing.
https://www.bosterbio.com/msds?sku=A07319-1
68 kDa
68 kDa
6
IgG
Each vial contains 4 mg Trehalose, 0.9 mg NaCl, 0.2 mg Na2HPO4.
Beschrijving
Boster Bio Anti-GLMN Antibody Picoband® catalog # A07319-1. Tested in WB, Flow Cytometry, ELISA applications. This antibody reacts with Human, Mouse, Rat. T
Specificaties
Recent bekeken producten

Cellubrevin Antibody
MBS9436639-01
0.05 mL

Oxidative Stress Combo Assay Tissue Kit
EA-7008
1 Each

Arachis hypogaea Lectin (PNA) - Biotinylated
21510020-1
5mg

1,4- Dioxane Pure
1041330 500
500 mL

Benzonase ELISA Kit
EG23601S
96 Tests

Not I Restriction Enzyme
B2016623
500 Units

K562-HLA-G0101 Overexpressing Cell Line
RG-1214
5x 10^6

Yeast Poly (A) Polymerase
RNT-006-S
30000 Units
Recent gezochte producten

Cellubrevin Antibody
MBS9436639-01
0.05 mL

Rat Oxidative Stress Primer Library
ROSL-I
1 set

DTNB (Ellman’s) Thiol Oxidative Stress Assay
1021
1 Kit

OSR1 (Oxidative Stress Responsive 1)
MBS616581-01
0.1 mL

Oxidative Stress Combo Assay Cell Kit
EA-7006
1 Each

Oxidative Stress Combo Assay Blood Kit
EA-7007
1 Each

Oxidative Stress Combo Assay Tissue Kit
EA-7008
1 Each

OSR1 (Oxidative Stress Responsive 1)
O8054
100 µL
