Atomaire absorptiespectrofotometer
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
Atomic Absorption Spectrophotometer 15A-AAS102is designed with the latest technology, can automatically accomplish safety ignition and reproducibility of the flame method. The graphic analysis system gives information on analysis of the whole process e.g. measured value, temperature, procedures, time, etc. It consist of hollow cathode lamp to improve the analysis efficiency and accuracy of the flame & deuterium lamp for background correction.
Wavelength range: 180 to 900 nm Spectral Bandwidth: 0,0.2,0.4,1.0,2.0nm (Automatic setting) Wavelength accuracy: ≤ 0.15 nm Wavelength repeatability: ± 0.1 nm Baseline drift: ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic) Absorbance Range: 0 - 4 A Detector: Imported photomultiplier tube Lamp holder: ≤ 6 lamps automatic turret, automatic alignment Lamp power supply mode: pulsed power supply Optical System: large 1800 /mm grating ruling, full closed optical system Atomization Chamber: Polymer explosion-proof spray chamber Characteristic concentration (Cu) : 0.015 μg / mL / 1 % Detection Limit (Cu) : 0.002 μg/mL Burner: Full titanium combustion head, 50 mm or 100 mm general combustion head Nebulizer: Atomizer efficient glass atomizer, can also be customized Precision: RSD ≤ 0.5 % Ignition Type: Microcomputer control, automatic ignition Gas Control: Automatic gas control system Measurement: Flame method, Hydride generation-Atomic absorption method Concentration calculation: Standard curve method (1 - 3 times curve), automatic fitting The number of repeated measurements: 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. Print results: Print the final stages of test data or analysis. The results can be exported into Excel worksheet. Power supply: 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.
Monochromator :Czerny-Turner Wavelength range :190 to 900 nm Spectral Bandwidth :0.2,0.4,1.0,2.0 nm, multi-speed automatic switching Wavelength accuracy :± 0.25 nm
Beschrijving
Atomic Absorption Spectrophotometer 15A-AAS102is designed with the latest technology, can automatically accomplish safety ignition and reproducibility of the fl
Specificaties
Recent bekeken producten

Cellubrevin Antibody
MBS9436639-01
0.05 mL

Oxidative Stress Combo Assay Tissue Kit
EA-7008
1 Each

Arachis hypogaea Lectin (PNA) - Biotinylated
21510020-1
5mg

1,4- Dioxane Pure
1041330 500
500 mL

Benzonase ELISA Kit
EG23601S
96 Tests

Not I Restriction Enzyme
B2016623
500 Units

K562-HLA-G0101 Overexpressing Cell Line
RG-1214
5x 10^6

Yeast Poly (A) Polymerase
RNT-006-S
30000 Units
Recent gezochte producten

Cellubrevin Antibody
MBS9436639-01
0.05 mL

Rat Oxidative Stress Primer Library
ROSL-I
1 set

DTNB (Ellman’s) Thiol Oxidative Stress Assay
1021
1 Kit

OSR1 (Oxidative Stress Responsive 1)
MBS616581-01
0.1 mL

Oxidative Stress Combo Assay Cell Kit
EA-7006
1 Each

Oxidative Stress Combo Assay Blood Kit
EA-7007
1 Each

Oxidative Stress Combo Assay Tissue Kit
EA-7008
1 Each

OSR1 (Oxidative Stress Responsive 1)
O8054
100 µL