Atomaire absorptiespectrofotometer
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
Atomic Absorption Spectrophotometer 15A-AAS103 comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of 1800/mm reticle large are grating monochromator and titanium burner to improve the analysis efficiency and accuracy of the flame. Atomic Absorption spectrophotometer has manual 3 lamp holder configuration & 3 independent lamp power supply for analysis.
Wavelength range: 180 to 900 nm Spectral Bandwidth: 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover) Wavelength accuracy: ≤ 0.15 nm Wavelength repeatability: ± 0.1 nm Baseline drift: ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic) Absorbance Range: 0 - 4 A Lamp holder: ≤ 3 lamps automatic turret, automatic alignment Lamp power supply mode: pulsed power supply Optical System: large 1800 /mm grating ruling, full closed optical system Atomization Chamber: Polymer explosion-proof spray chamber Characteristic concentration (Cu) : 0.015 μg / mL / 1 % Detection Limit (Cu) : 0.002 μg/mL Burner: Full titanium combustion head, 50 mm or 100 mm general combustion head Nebulizer: Atomizer efficient glass atomizer, can also be customized Precision: RSD ≤ 0.5 % Ignition Type: Microcomputer control, automatic ignition Gas Control: Automatic gas control system Measurement: Flame method, Hydride generation-Atomic absorption method Concentration calculation: Standard curve method (1 - 3 times curve), automatic fitting The number of repeated measurements: 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. Print results: Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.
Monochromator :Czerny-Turner Wavelength range :190 to 900 nm Spectral Bandwidth :0.2,0.4,1.0,2.0 nm, multi-speed automatic switching Wavelength accuracy :± 0.25 nm
Beschrijving
Atomic Absorption Spectrophotometer 15A-AAS103 comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of
Specificaties
Recent bekeken producten

Optical EtBr filter, 610 nm for SmartView Pro Imager System, 1100 & 2100 series (for UV)
UVCI-1100-EB
1 Unit

AGPAT4 Antibody
MBS7124622-01
0.05 mL

H&E Mount, Permanent Mountindg media for coverslipping H&E stains from water,
NB315
125 mL

SCD polyclonal antibody
GTR18043932-01
50 μL

(KO Validated) SUMO1 Polyclonal Antibody
E-AB-92410-01
60 µL

Salicylate hydroxylase, Microorganism
HY-E70520-01
1 KU

Purified Diphtheria Toxoid protein (cGMP/USP, vaccine grade, ~1500-2500 Lf/ml; Low endotoxin)
DTOX16-N-500
500 µg

BioCoupler® Glass Set (16 oz) x12
BCS1612
12 Each
Recent gezochte producten

M-90-422 AF Systems Consumables
131576
Box of 180 Label(s)

Consumable Pack M996030
WAT1096
1 Each

Consumable Pack M996039
WAT1108
1 Each

Consumable Pack M996034
WAT1106
1 Each

Consumable Pack M996038
WAT1102
1 Each

Consumable Pack M996037
WAT1098
1 Each

Consumable Pack M996043
WAT1088
1 Each

Gene gun consumables
E1653
1 Unit