Atomaire absorptiespectrofotometer
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
Atomic Absorption Spectrophotometer LX700AAS is designed for air-acetylene flame method analysis, flame emission method analysis and graphite furnace analysis etc. Equipped with unique light source system, with 8-lamp turret fully automatic change and optimization, supports 1 lamp working and 7 lamps preheating in the same time. Flame temperature is continuously adjustable between Room temperature~3000ºC, which makes it possible to choose the best atomization temperature. Flame will not pollute the environment and is not harmful for human bodies. It’s a break-through in flame AAS analysis.
Used for testing the metal element concentration analyze in agriculture, chemical, environmental study, food, mining, and petrochemical, pharmaceutical industry.
Provided with automatic 8-lamp turret, automatic adjustment of lamp current and optimization of light beam position To perform flame emission analysis, flame emission burner head can be installed for alkali metals Parameters like Wavelength scanning, peak picking, change in spectral bandwidth, optimization of position parameters, automatic ignition and gas flow setting are done automatically Data processing system: provided with analytical methods – Working curve auto-fitting standard addition method, automatic sensitivity correction, automatic calculation of concentration and content with windows operating system software Experiments can be repeated 1~99 times along with automatic calculation of mean value, standard deviation and relative standard deviation Equipped with multi task functions- sequential determination of multi-elements in the same sample, condition reading- with model function and result printing- measured data and final analytical report printout in excel Provided with standard RS-232 serial port connection AAS analysis is made under windows operating system which is easy-to-use with fast parameter setting and optimization In order to increase the sensitivity in flame analysis, two high performance HCLs can be mounted on the lamp turret The D2 lamp and S-H background correction capability at 1A and 1.8A respectively is better than 30 times The optical system consisting of outer light path, C-T type grating monochromatic, and back light path, which is in the upper right of the instrument, is controlled by the computer Real-time monitoring of flame status, air pressure, etc. Automatically shutting off the gas circuit and alarm in abnormal status Equipped with alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system Protection function and alarms for insufficient carrier gas and protective gas pressure, insufficient cooling rate supply and over-heating in graphite furnace system
Atomic Absorption Spectrophotometer LX700AAS
Beschrijving
Atomic Absorption Spectrophotometer LX700AAS is designed for air-acetylene flame method analysis, flame emission method analysis and graphite furnace analysis e
Specificaties
Recent bekeken producten

Benzonase ELISA Kit
EG23601S
96 Tests

Not I Restriction Enzyme
B2016623
500 Units

K562-HLA-G0101 Overexpressing Cell Line
RG-1214
5x 10^6

Yeast Poly (A) Polymerase
RNT-006-S
30000 Units

Arachis hypogaea Lectin (PNA) - Biotinylated
21510020-1
5mg

Arachis hypogaea lectin (PNA)
05-0116-10mg
10 mg

Anti-APOE2 mouse monoclonal antibody
TD-AB0132
100 µg

Human Apolipoprotein E2 (Apo E2) Antibody
22210-05011
150 µg