CellSurface FLOW Staining Kit
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
The Cell Surface FLOW Staining Kit allows the detection of antibodies on the cell surface proteins in flow cytometry analysis. This kit is specially formulated to reduce non-specific staining of fluorochrome-labelled antibodies and to increase fluorescence signaling. This buffer can be used for cell and antibody dilution steps, as well as wash steps for the cell surface staining and flow cytometric analysis. This buffer contains fetal bovine serum (FBS) to help reduce the non-specific binding of antibodies.
FACS
Staining Buffer 1X (4 x 60 mL) Fixation Buffer 10% (15 mL)
Store at 2-8°C
Protocol: 1. Determine number of cells required for staining. Each sample contains 0.5 -1 x 106 cells in 50 μl of media or Staining Buffer. The following controls are needed for the experiment. Unstained cells (no antibodies were added), cells with isotype control and cells with secondary antibody (if secondary antibody was used) . 2. Cetrifuge cells at 1000 RPM for 10 minutes and decant supernatant. 3. Resuspend pellet with appropriate volume of 1X Staining Buffer. 4. Aliquote 1x106 cells in 50 μl to the desired number of flow tubes. Dilute primary antibodies in 50 μl of 1X Staining Buffer. Add diluted antibodies into 50 μl of cells. Mix antibodies in cells suspension thoroughly. 5. Incubate in ice for 30 minutes. Wash cells in 2-3 ml of 1X Staining Buffer. Centrifuge 1000 RPM for 10 minutes. Decant supernatant carefully. If primary antibody is fluorescent-labeled, resuspend pellet in 300-400 μl of Staining Buffer, analyze samples. Protected from light. If primary antibody is not labeled, proceed with step 6. 6. Dilute secondary antibody (PE, FITC, APC or biotin labeled) in 50 μl Staining Buffer per sample. 7. Resuspend cells in diluted secondary antibody. Incubate in ice for 30 minutes. (protected from light) . 8. Wash cells in 3-4 ml of staining buffer. Cetrifuge at 1000 RPM for 10 minutes. Decant supernatant. 9. After decanting, add 300-400 μl of Staining Buffer to each tube. If not analyzing same day, resuspend cells in 1% Fixation Buffer (10% can be diluted to 1% using staining buffer) . Samples can be stored over night in dark at 4°C. Samples can be analyzed in flow cytometer according to the manufacturer protocol.
Beschrijving
The Cell Surface FLOW Staining Kit allows the detection of antibodies on the cell surface proteins in flow cytometry analysis. This kit is specially formulated
Specificaties
Recent bekeken producten

Biotin-Recombinant (sf9) Marburg virus glycoprotein (Musoke, HA-tag, >95%), purified
MVGP16-BTN
100 µL

MARV VP40/Marburg VP40 Protein (N-His, Lake Victoria marburgvirus (strain Musoke-80) (MARV) (Marburg virus (strain Kenya/Musoke/1980) ) )
P505862
100 µg

Hettich Centrifuge Rotanta 460R Refrigerated Large Volume
CEN0703
1 Each

X4RF Refrigerated Centrifuge
75009936
1 Each

Drug Stability Chamber
500-DSC102
1 Unit

Modular Incubator Chamber
MIC-101
1 Unit

CYP707A2 Antibody
GTR17947107
2 mg

SsDNA Assay Kit
12645ES60
100 Tests
Recent gezochte producten

Biotin-Recombinant (sf9) Marburg virus glycoprotein (Musoke, HA-tag, >95%), purified
MVGP16-BTN
100 µL

MARV VP40/Marburg VP40 Protein (N-His, Lake Victoria marburgvirus (strain Musoke-80) (MARV) (Marburg virus (strain Kenya/Musoke/1980) ) )
P505862
100 µg

X4RF Refrigerated Centrifuge
75009936
1 Each

Low Speed Refrigerated Centrifuge
LX104LSR
1 Unit

Low Speed Refrigerated Centrifuge
LX117LSR
1 Unit

Low Speed Refrigerated Centrifuge
LX124LSR
1 Unit

Blood Bank Refrigerator
LX4000BBR
1 Unit

Blood Bank Refrigerator
LX4002BBR
1 Unit