CLIA Kit voor Ethinylestradiol (EE)
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
Ethinyl Estradiol ; Ethynyl Estradiol; Ethinyl Oestradiol
Chemiluminescent immunoassay for Antigen Detection.
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Ethinylestradiol (EE) . A competitive inhibition reaction is launched between biotin labeled Ethinylestradiol (EE) and unlabeled Ethinylestradiol (EE) (Standards or samples) with the pre-coated antibody specific to Ethinylestradiol (EE) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Ethinylestradiol (EE) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Ethinylestradiol (EE) level in the sample or standard.
2h
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
7.81-2,000pg/mL
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Ethinylestradiol (EE) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Ethinylestradiol (EE) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
The minimum detectable dose of this kit is typically less than 2.97pg/mL
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
48T, 96T, 96Tx5, 96Tx10, 96Tx100
This assay has high sensitivity and excellent specificity for detection of Ethinylestradiol (EE) . No significant cross-reactivity or interference between Ethinylestradiol (EE) and analogues was observed.
Ethinylestradiol
Competitive Inhibition
Pan-species (General)
Beschrijving
CLIA Kit voor Ethinylestradiol (EE) Beschikbaar in 24 Tests. Bestel eenvoudig online met snelle levering.
Specificaties
Recent bekeken producten

3-D Life Dextran-PEG Hydrogel SG
G92-1
1 Each

Plant Preservative Mixture (PPM)
P5550-01
25 mL

PhaseShield™ Gel Tubes, Heavy (50x 2ml)
M2302-05H
50x 2 mL

Parvovirus B19
OT020
1 Each

Anti- Protein A Antibody
GWB-E66F30
1 mL

Recombinant TAFV GP1 Protein, C-Fc
EVV03609
100 μg

Gabbr1 Mouse Monoclonal Antibody [Clone ID: S93A-49]
TA326530
100 µg

BSA-Myc/DDK Control Protein
AR100025
50 µL