
CLIA Kit voor Tetraspanin 30Cluster van Differentiatie 63 (CD63)
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
TSPAN30; LAMP-3; ME491; MLA1; OMA81H; Melanoma 1 antigen; Granulophysin; Lysosomal-associated membrane protein 3; Ocular melanoma-associated antigen
P08962
Chemiluminescent immunoassay for Antigen Detection.
Signal transduction; CD & Adhesion molecule; Hematology; Developmental science
The microplate provided in this kit has been pre-coated with an antibody specific to Tetraspanin 30Cluster of Differentiation 63 (CD63) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Tetraspanin 30Cluster of Differentiation 63 (CD63) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Tetraspanin 30Cluster of Differentiation 63 (CD63) level in the sample or standard.
2h, 40min
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
13.7-10,000pg/mL
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Tetraspanin 30Cluster of Differentiation 63 (CD63) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Tetraspanin 30Cluster of Differentiation 63 (CD63) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
The minimum detectable dose of this kit is typically less than 5.1pg/mL
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
48T, 96T, 96Tx5, 96Tx10, 96Tx100
This assay has high sensitivity and excellent specificity for detection of Tetraspanin 30Cluster of Differentiation 63 (CD63) . No significant cross-reactivity or interference between Tetraspanin 30Cluster of Differentiation 63 (CD63) and analogues was observed.
Tetraspanin 30Cluster of Differentiation 63
Double-antibody Sandwich
Homo sapiens (Human)
Beschrijving
CLIA Kit voor Tetraspanin 30Cluster van Differentiatie 63 (CD63) Beschikbaar in 24 Tests. Bestel eenvoudig online met snelle levering.
Specificaties
Recent bekeken producten

Sodium taurocholate
529535
5.0g

Sodium Taurocholate
289448-01
5 g

Universal Lateral Flow Assay Kit (FAM Gold)
AU2034-05
3 Lines

HDV Ab ELISA (ELISA Kit) [CE]
KAPDDAB
96 Tests

300ul Rainin LTS tip, with filter, Bulk pack, low retention
RT300BF-L
1000 PCS/Bag - 20Bag/Case

3-D Life Dextran-PEG Hydrogel SG
G92-1
1 Each

Plant Preservative Mixture (PPM)
P5550-01
25 mL

PhaseShield™ Gel Tubes, Heavy (50x 2ml)
M2302-05H
50x 2 mL
Recent gezochte producten

HDV
hdv-234
100µg

H-D-Val-OMe · HCl
4025305.0005
5 g

H-D-Val-OH
F-2180.0025
25.0g

H-D-Val-2-chlorotrityl resin (200-400 mesh, 0.50-0.90 mmol/g)
D-2990.0005
5.0g

H-D-Val-Leu-Arg-pNA · 2 AcOH
L-1885.0250
250.0mg

H-D-Val-Leu-Lys-chloromethylketone
N-1385.0025
25.0mg

genesig Easy kit for Hepatitis D Virus
Z-Path-HDV-EASY
50 Tests

genesig Standard Real-time PCR detection kit for HDV
Z-Path-HDV-std
150 Tests
