
ELISA Kit voor Acyl Co-enzym A dehydrogenase, C4-To-C12 Straight Chain (ACADM)
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
MCAD; MCADH; ACAD1; Medium-chain specific acyl-CoA dehydrogenase, mitochondrial
P11310
Enzyme-linked immunosorbent assay for Antigen Detection.
Enzyme & Kinase
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain (ACADM) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain (ACADM) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain (ACADM), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain (ACADM) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
3h
Tissue homogenates, cell lysates and other biological fluids
0.312-20ng/mL
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain (ACADM) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain (ACADM) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
The minimum detectable dose of this kit is typically less than 0.113ng/mL
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
48T, 96T, 96Tx5, 96Tx10, 96Tx100
This assay has high sensitivity and excellent specificity for detection of Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain (ACADM) . No significant cross-reactivity or interference between Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain (ACADM) and analogues was observed.
Acyl Coenzyme A Dehydrogenase, C4-To-C12 Straight Chain
Double-antibody Sandwich
Homo sapiens (Human)
Beschrijving
ELISA Kit voor Acyl Co-enzym A dehydrogenase, C4-To-C12 Straight Chain (ACADM) Beschikbaar in 24 Tests. Bestel eenvoudig online met snelle levering.
Specificaties
Recent bekeken producten

Recombinant BoHV-1 Envelope glycoprotein E
DRA167-01
50 µg

GelRed® Agarose LE
#41029-5G
1x 5 g

50 ml Disposable Serological Pipette
CPP00050
100/CS

Sodium taurocholate
529535
5.0g

Sodium Taurocholate
289448-01
5 g

Universal Lateral Flow Assay Kit (FAM Gold)
AU2034-05
3 Lines

HDV Ab ELISA (ELISA Kit) [CE]
KAPDDAB
96 Tests

300ul Rainin LTS tip, with filter, Bulk pack, low retention
RT300BF-L
1000 PCS/Bag - 20Bag/Case
Recent gezochte producten

Recombinant BoHV-1 Envelope Glycoprotein D
DRA186-01
50 µg

BoHV-1 gE/Glycoprotein E Polyclonal Antibody
GTR18776801-01
50 µg

Recombinant BoHV-1 gD/Glycoprotein D, C-Fc
GTR19146511-01
50 µg

Recombinant BoHV-1 gE/Glycoprotein E, N-His
GTR19146515-01
50 µg

BoHV-1 gE/Glycoprotein E, N-His
ARO-P18517-01
50 µg

BoHV-1 gD/Glycoprotein D, N-His
ARO-P18516-01
50 µg

BoHV-1 gD/Glycoprotein D, C-His
ARO-P18515-01
50 µg

BoHV-1 gD/Glycoprotein D, C-Fc
ARO-P18514-01
50 µg
