EOB ELISA
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
The EPO ELISA Kit is intended to measure Erythropoietin (EPO) levels in human serum in 2.5 hours. This assay is intended for research use, as an aid in the diagnosis of anemias and polycythemias. With the advent of the administration of recombinant erythropoietin as a biologic therapy to increase red blood cell mass, an erythropoietin assay may be used also to aid in the prediction and monitoring of response to recombinant erythropoietin treatment in persons with anemias. Erythropoietin (EPO) is a heavily glycosylated protein with a molecular weight of about 30,000 - 34,000 Daltons. Human EPO is a polypeptide consisting of 165 amino acids, containing one O-linked and three N-linked carbohydrate chains. The recombinant EPO is a good substitute for the native protein for use in an immunoassay. Serum EPO levels are dependent on the rate of production and the rate of clearance of the protein. Ninety percent of EPO is produced in the peritubular cells of the adult kidney in response to a decrease in tissue oxygenation. There is evidence indicating that the protein on these cells which detects oxygen saturation of the blood is a heme-containing moiety. As the pO2 of the plasma, a function of the hematocrit decreases, EPO concentration will increase. There are also observations suggesting that normally there is an inverse correlation between serum EPO levels and red blood cell mass. Quantitation of serum erythropoietin concentration serves as a diagnostic adjunct in determining the cause of anemia or erythrocytosis. Aplastic anemia, hemolytic anemia and anemia due to iron deficiency all result in serum EPO elevation. Whereas, EPO levels in patients with secondary anemia due to renal failure and other disorders such as acquired immune deficiency syndrome (AIDS) are generally inappropriately low for the degree of anemia. This is mostly likely caused by an impaired ability of the diseased kidney to produce adequate quantities of EPO8. Low concentrations of EPO may give an early warning of kidney transplant rejection. EPO also can be used to monitor AIDS patients undergoing Zidovudine (AZT) therapy. An increased concentration of EPO verifies that anemia associated with AZT therapy is due to red cell hypoplasia or apliasia. Polycythemia rubra vera, or primary erythrocytosis (an increase of red blood cell mass) results from unstimulated over production of erythrocytes. Hence, the increase in the hemoglobin causes decreased production of EPO, which results in subnormal levels of serum EPO. Secondary polycythemias, which are also characterized by an increase in the total red blood cell mass, occur as a physiological response to elevated levels of circulatory EPO caused by tissue hypoxia. The hypoxia may be due to such factors as pulmonary fibrosis, cardiovascular disease, prolonged exposure to high altitude, abnormal forms of hemoglobin or drug treatment. Some tumors produce EPO and, in these cases, EPO may be used as a tumor marker to monitor the effectiveness of treatment.
The EPO ELISA Kit is intended to measure Erythropoietin (EPO) levels in human serum in 2.5 hours. This assay is intended for research use, as an aid in the diagnosis of...
ELISA
Serum
200 uL
1.2 mU/mL
2.5 hrs
Human
7.5 - 500 mU/mL
Beschrijving
The EPO ELISA Kit is intended to measure Erythropoietin (EPO) levels in human serum in 2.5 hours. This assay is intended for research use, as an aid in the diag
Specificaties
Recent bekeken producten

Simulated Dermal Fluid (BZ457) - 100 mL
BZ457-01
100 mL

Polyclonal BDNF Antibody
APG02253G
0.05mg

Biotin-Recombinant (sf9) Marburg virus glycoprotein (Musoke, HA-tag, >95%), purified
MVGP16-BTN
100 µL

MARV VP40/Marburg VP40 Protein (N-His, Lake Victoria marburgvirus (strain Musoke-80) (MARV) (Marburg virus (strain Kenya/Musoke/1980) ) )
P505862
100 µg

Hettich Centrifuge Rotanta 460R Refrigerated Large Volume
CEN0703
1 Each

X4RF Refrigerated Centrifuge
75009936
1 Each

Drug Stability Chamber
500-DSC102
1 Unit

Modular Incubator Chamber
MIC-101
1 Unit
Recent gezochte producten

Lysosomal Stress TF Activation Profiling Plate Array
FA-1012
12 Samples

Deleted in Azoospermia-Like (DAZL, DAZL1, DAZ Homolog, DAZH, DAZ-like Autosomal, DAZLA, MGC26406, SPGY-like-autosomal, SPGYLA)
MBS6009464-01
0.1 mL

Deleted in Azoospermia-Like (DAZL, DAZL1, DAZ Homolog, DAZH, DAZ-like Autosomal, DAZLA, MGC26406, SPGY-like-autosomal, SPGYLA)
MBS607856-01
2 mL

Optic Atrophy 1, Autosomal Dominant (OPA1) ELISA Kit
MBS2709526-01
24 Strip Well

Deleted in Azoospermia-Like (DAZL, DAZL1, DAZ Homolog, DAZH, DAZ-like Autosomal, DAZLA, SPGY-like-autosomal, SPGYLA)
313331
100 µL

Usher syndrome 1C (autosomal recessive, severe)
339156
100 µL

FXR2 (FMR1 Autosomal Homolog 2) discontinued
536504-01
30ul

Deleted in Azoospermia-Like (DAZL, DAZL1, DAZ Homolog, DAZH, DAZ-like Autosomal, DAZLA, SPGY-like-autosomal, SPGYLA)
D2675-02