Gaschromatografie
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
Gas chromatography system is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate tracking design and accurate programmed heating control system for the furnace temperature. Incorporated with safe and reliable functions of self-ignition and hydrogen leakage self-protection.
Chromatography column type: Capillary or Packed column Chromatography column length: 100 to 300 mm Chromatography column diameter: 0.2 to 0.5 mm Temperature operating range: Higher than the room temperature of 5 °C to 450°CLiquid nitrogen cold trap: -80 °C to 400 °CDry ice cold trap: -55 °C to 400 °C Maximum programmed heating speed: 120 °C/min Programmed temperature steps: 7 steps Temperature setting precision: 0.1 °C Programmed heating rate: 0.1 to 120 º C/min (increment of 0.1°C) The longest method run time: 999.99 min Furnace dimension: 280 x 300 x180 mm Heating area: Six individual controlling heating areasMaximum temperature in auxiliary heating area: 300 °C Detectors: Following detectors can be selected as per the requirement FID: Maximum using temperature: 450 °CMinimum LOD: ≤ 2.5 pg C / s [n - C16]Linear dynamic range: 107 (± 10 %) Data collection frequency: Maximum 100 Hz TCD: Maximum using temperature: 400 °CMinimum LOD: < 400 pg C3 H8 / ml (He) Linear dynamic range: 105 (± 5 %) Data collection frequency: Maximum 100 HzThe design of monofilament TCD and Micro-ECD FPD: Maximum using temperature: 250 °CMinimum LOD: < 4 pg S / sec, < 1 pg P/secLinear dynamic range: > 103 (S), > 104 (P) Optional: 105g S / g C, 106g P / g C ECD: Maximum using temperature: 400 °CType of gas compensation detector: 5 % methane, argon, nitrogenMinimum LOD: > 107S, > 107PLinear dynamic range: 5 x 105Data collection frequency: Maximum 100 HzRadioactive source: < 12 mCi 63 Ni NPD: Maximum using temperature: 450 °CMinimum LOD: < 0.2 pg N / sec, < 0.2 pg P / secMinimum LOQ: < 3 pg / secLinear dynamic range: 105N, 105P
Used in quality supervision of medicines, foods and chemicals, oil extraction and refining industry, petrochemical industry, electronic high-purity gas industry and scientific research institutes.
Chromatography column type :Capillary and Packed column Chromatography column length :100 to 500 mm Chromatography column diameter :0.2 to 0.5 mm Temperature operating range :Higher than the room temperature of 5 °C to 450 °C
Beschrijving
Gas chromatography system is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate
Specificaties
Recent bekeken producten

DiagPoly™ Carboxyl Fluorescent Polystyrene Particles, Green, 1 µm
DCFG-L007
1 mL

DiagPoly™ Carboxyl Polystyrene Particles, 1.0 µm
DNM-F029
10 mL

DiagPoly™ Carboxyl Fluorescent Polystyrene Particles, Green, 0.2 µm
DCFG-L004
1 mL

Optical EtBr filter, 610 nm for SmartView Pro Imager System, 1100 & 2100 series (for UV)
UVCI-1100-EB
1 Unit

AGPAT4 Antibody
MBS7124622-01
0.05 mL

H&E Mount, Permanent Mountindg media for coverslipping H&E stains from water,
NB315
125 mL

SCD polyclonal antibody
GTR18043932-01
50 μL

(KO Validated) SUMO1 Polyclonal Antibody
E-AB-92410-01
60 µL
Recent gezochte producten

DiagPoly™ Carboxyl Fluorescent Polystyrene Particles, Green, 1 µm
DCFG-L007
1 mL

DiagPoly™ Carboxyl Polystyrene Particles, 1.0 µm
DNM-F029
10 mL

DiagPoly™ Carboxyl Fluorescent Polystyrene Particles, Green, 0.2 µm
DCFG-L004
1 mL

M-90-422 AF Systems Consumables
131576
Box of 180 Label(s)

Consumable Pack M996030
WAT1096
1 Each

Consumable Pack M996039
WAT1108
1 Each

Consumable Pack M996034
WAT1106
1 Each

Consumable Pack M996038
WAT1102
1 Each