Gasmengsysteem
Kwaliteit
ISO Gecertificeerd
Levering
24-48 uur
Technische Specificaties
The GMS-5003 is a state-of-the-art flow-through oxygen (O2) sensor that delivers rapid and precise oxygen readings from 0% to 25%. It becomes the ultimate tool for achieving precise mixtures of custom O2 concentrations when used with our Dual Flow Meter (DFM-3002) . It is particularly beneficial for creating hypoxic culture conditions or when specialized pre-mixed gases are costly or unavailable. The GMS-5003 has an advanced (self-calibrating) oxygen sensor, which measures the oxygen partial pressure (pO2) . Furthermore, integrated internal pressure, temperature, and humidity sensors work in concert to provide a comprehensive dataset, converting pO2 readings into accurate oxygen percentages. Unlike traditional electrochemical or galvanic sensors, the GMS-5003 boasts integrated solid-state sensors that eliminate the need for replacements or recalibrations. These sensors are factory-calibrated to account for ambient temperature, pressure, and humidity variations, ensuring precise performance across a broad environmental spectrum. The system is user-friendly, stable, durable, devoid of hazardous materials, and exhibits negligible cross-sensitivity to other gases such as CO2 and N2. How it works? - The Gas Mixing System (GMS-5003) is designed to be used in-line with the Dual Flow Meter (DFM-3002) to precisely measure the percentage of oxygen for flushing and filling the Modular Incubator Chamber (MIC-101) . See the instruction sheet for detailed protocols.
Dimensions: Height: 4.45 cm (1.75 in) . Width: 17.15 cm (6.75 in) . Depth: 6.35 cm (2.5 in) . Weight: 541.5 g (19.1 oz) . Oxygen Sensor Technology: Solid-state fluorescence quenching, diffusion sampling Range: 0 – 25% pO2 Accuracy: <2% FS/0.1 mbar Resolution: 0.1% Operating conditions: -30°C to 60°C, 500-1200 mbar Temperature Sensor Range: -40°C to 125°C Accuracy tolerance: ±0.2°C (0°C to 90°C) Resolution: 0.01°C Long-term drift (max) : <0.03°C/year Humidity Sensor Range: 0% RH to 100% RH Accuracy tolerance: ±2% RH Resolution: 0.01% RH Hysteresis: ±0.8% RH (@25°C) Long-term drift (typical) : <0.25% RH/year Barometric Pressure Sensor Range: 500-1200 mbar Accuracy tolerance: 5 mbar Resolution: 1 mbar
Easy to Use. Rechargeable, Long Battery Life. Accurate: O2 range 0-25%. Reliable. Small and Compact. Low Cost. Maintenance-Free. Factory Calibrated: ready-to-use out of the box. Also measures temperature, humidity, and barometric pressure.
Beschrijving
The GMS-5003 is a state-of-the-art flow-through oxygen (O2) sensor that delivers rapid and precise oxygen readings from 0% to 25%. It becomes the ultimate tool
Specificaties
Recent bekeken producten

Biotin-Recombinant (sf9) Marburg virus glycoprotein (Musoke, HA-tag, >95%), purified
MVGP16-BTN
100 µL

MARV VP40/Marburg VP40 Protein (N-His, Lake Victoria marburgvirus (strain Musoke-80) (MARV) (Marburg virus (strain Kenya/Musoke/1980) ) )
P505862
100 µg

Hettich Centrifuge Rotanta 460R Refrigerated Large Volume
CEN0703
1 Each

X4RF Refrigerated Centrifuge
75009936
1 Each

Drug Stability Chamber
500-DSC102
1 Unit

Modular Incubator Chamber
MIC-101
1 Unit

CYP707A2 Antibody
GTR17947107
2 mg

SsDNA Assay Kit
12645ES60
100 Tests