Humane MYL3 (myosine lichtketen 3, alkaline, ventriculaire, trage skelet) ELISA Kit
Gecertificeerd

Humane MYL3 (myosine lichtketen 3, alkaline, ventriculaire, trage skelet) ELISA Kit

Catalog #: ELK4927-01
Maat: 48 Tests

Kwaliteit

ISO Gecertificeerd

Levering

24-48 uur

Prijs -1%
Login voor prijs
BTW niet inbegrepen
Gratis verzending vanaf €100
Technische Documentatie

Technische Specificaties

Description

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MYL3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MYL3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MYL3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MYL3 in the samples is then determined by comparing the OD of the samples to the standard curve.

Product Name Alternative

CMH8; MLC1V; VLC1; MLC1SB; Cardiac myosin light chain 1; Ventricular/slow twitch myosin alkali light chain

UniProt

P08590

Reactivity

Human

Field of Research

Metabolic pathway

Assay Type

Sandwich

Assay Principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MYL3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MYL3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MYL3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MYL3 in the samples is then determined by comparing the OD of the samples to the standard curve.

Assay Performance Time

3.5h

Standard

5000 pg/mL

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

78.13-5000 pg/mL

Sensitivity

29 pg/mL