Low Sample Volume ELISA Kit voor Amylin
Gecertificeerd

Low Sample Volume ELISA Kit voor Amylin

Catalog #: TRV-055294-01
Maat: 24 Tests

Kwaliteit

ISO Gecertificeerd

Levering

24-48 uur

Prijs -1%
Login voor prijs
BTW niet inbegrepen
Gratis verzending vanaf €100

Technische Specificaties

Product Name Alternative

IAPP; IAP; DAP; Islet Amyloid Polypeptide; Insulinoma Amyloid Polypeptide; Diabetes-associated peptide

Applications

Enzyme-linked immunosorbent assay for Antigen Detection.

Field of Research

Metabolic pathway; Endocrinology; Hepatology

Assay Principle

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Mini Samples Amylin has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Mini Samples Amylin and unlabeled Mini Samples Amylin (Standards or samples) with the pre-coated antibody specific to Mini Samples Amylin. After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Mini Samples Amylin in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Mini Samples Amylin in the sample.

Assay Performance Time

3h

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

12.35-1,000pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Mini Samples Amylin were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Mini Samples Amylin were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 4.37pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Mini Samples Amylin. No significant cross-reactivity or interference between Mini Samples Amylin and analogues was observed.

Product Name Synonym

Amylin

Method

Competitive Inhibition

Organism Species

Rattus norvegicus (Rat)

Beschrijving

Low Sample Volume ELISA Kit voor Amylin Beschikbaar in 24 Tests. Bestel eenvoudig online met snelle levering.

Specificaties

ProductnaamLow Sample Volume ELISA Kit voor Amylin
Categorie
Beschikbare grootte24 Tests
CatalogusnummerTRV-055294-01